Abstract
Aim: The aim of this study is to evaluate radiographically the quality of root canal filling in mesiodistal and buccolingual view when comparing matched cone condensation and warm lateral Gutta-percha condensation using system B heating instrument in a low-heat warm lateral condensation technique in0 vitro. Materials and Methods: A total of 40 mandibular premolars with straight single canals were divided into two groups with 20 each. The root canals were shaped by hand file and Revo-S rotary files to size (25, 0.06) at the end point, then they filled by Gutta-percha cone and meta-seal sealer. In group A, a single matched cone technique was used to fill the root canals. In group B, a hot lateral condensation using system B instrument at 101°C was performed. Result: The result of this study showed no significant difference in density of Gutta-percha fill in apical and coronal two-third when comparing matched cone root canal filling and hot lateral technique (P > 0.05). The only significant difference (P < 0.05) was in matched cone between buccolingual and mesiodistal view in the coronal two-third. Conclusion: Within the limitation of this study, single matched cone technique has a good density in the apical one-third as that of the hot lateral technique so it may be used for filling narrow canals. In the coronal two-third of the root canal, single matched cone technique showed inferior density of root canal filling which can be improved by using accessory cones Gutta-percha in wide canal.