Abstract
Geothermal brine can be used as a heating liquid for pasteurization unit either by directly use the brine to heat up the raw milk, or by heating secondary fresh water. The geothermal brine can be obtained directly from geothermal well or from geothermal power plant separator. Unlike conventional pasteurization, the flow rate and temperature of geothermal brine might fluctuate due to many factors such as rain, well decline, and well shut down. Inherently the geothermal reservoir tends to decline in pressure and temperature. If the geothermal brine is obtained from geothermal power plant, then the flow rate and temperature of geothermal brine itself is susceptible to many changes in plant’s operation. A control system is needed for such utilization of geothermal brine. Simulation has been carried out to study the effect of PID feedback controller under geothermal brine temperature and flow rate disturbance. The result shows that PID controller could be used to compensate such disturbance. The PID controller controls milk inlet flow rate to balance the effect of both disturbances.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.