Abstract
A Central Solenoid (CS) conductor layout has been tentatively decided during the conceptual design phase of the Chinese Fusion Engineering Testing Reactor (CFETR). To check the validity of the conductor layout, stability analysis must be performed against the working condition of the conductors. We constructed a superconducting critical surface of the strands used in the CS conductors and then calculated the current sharing temperature of the conductors under the most stringent working condition envisioned with the operation parameters. We further analyzed the energy margin by simulating the quenching behavior with the GANDALF code upon disturbances of different durations and lengths representative of a mechanical disturbance and plasma disruption. The analysis results give preliminary estimation of conductor stability for further improvement of the design.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.