Abstract
Leakage current is one of the critical aspects to consider for overhead transmission line insulator’s condition and performance assessment. As the leakage current increase, the size of the dry band also will increase leads to the dry band arcing, deteriorate the insulator performance and contribute to the development of insulator flashover. Based on the literature study, other than the existence of contaminations on the surface of insulator combined with moisture, the variation in leakage current is also affected by the environmental and electrical stresses. Previous researches have shown the effect of environmental and electrical stresses on surface leakage current based on experimental and simulation results. This paper outlines an analytical approach based on dimensional analysis to propose a new mathematical model of leakage current under environmental and electrical stresses. To justify the applicability of the derived dimensional model, the new model has been validated using previous researcher’s experimental results. The validation indicated that the proposed model had shown a good agreement with the previous experimental results. The proposed dimensional equation for this research work can be potentially used as a predictive performance model to evaluate and monitor the leakage current and insulator’s performance
Highlights
Transmission line insulator, known as overhead insulator is greatly affected by the environmental stresses produced by the weather and surroundings
This paper presents the mathematical relationship to describe the leakage current (LC), considering the environmental and electrical factors using the analytical approach of dimensional analysis (DA)
The present article describes an analytical approach on modeling the LC of insulator under environmental and electrical stresses based on DA technique
Summary
Transmission line insulator, known as overhead insulator is greatly affected by the environmental stresses produced by the weather and surroundings. Insulator is usually exposed to uncertain weather and environmental pollution [1] such as inert material, soluble salt, water, electronic conductive dust, chemicals, industrial contaminants, and agricultural pollutants [2, 3]. Due to this variety of pollutions, insulator’s external surface becomes contaminated and tends to accumulate the contamination, allowing the leakage current (LC) to flow. This paper presents the mathematical relationship to describe the LC, considering the environmental and electrical factors using the analytical approach of dimensional analysis (DA). By using DA approach, the physical phenomenon is represented by dimensionally correct equation among certain variables [22, 23]
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have