Abstract

A standardised suction technique has been used to sample plasma proteins in dermal interstitial fluid (IF) serially for 5 to 6 days from a suction-induced skin mini-erosion. Increased protein concentrations ascribed to inflammation have been shown from day 1 onward. In this study, we assessed the effect of two different extraction pressures on IF sample composition. Total protein concentration and the concentrations of insulin, prealbumin, albumin, transferrin, IgG and alpha-2-macroglobulin were assessed daily in healthy volunteers. Samples were extracted at 50 mmHg and 200 mmHg below the atmospheric. At 0 h after forming the erosion, mean total IF protein content (relative to plasma) was lower in the samples extracted at -200 mmHg than at -50 mmHg (26 +/-13% (SD) vs 48 +/-9.8%; p < 0.05). There were no significant differences at 24, 48, 72 or 96 h. Of the individual proteins, expressed as area units (AU) for area under the curve (AUC) from 0-96 h, albumin was lower in IF sampled at -200 mmHg (2.49 +/- 0.68 vs 3.08 +/- 0.36 AU; p < 0.05), as was transferrin (1.91 +/- 0.52 vs 2.40 +/- 0.42 AU; p < 0.05). Extraction volumes were significantly higher at -200 mmHg (AUC diff: 60%; p < 0.05). Samples of IF extracted at 0 h at -200 mmHg contained lower protein concentrations, indicating an increased water fraction and an intact sieve function of the vascular wall. The difference in protein concentration extracted at higher and lower pressure from 24 h onward was less pronounced. Lower pressure should be used to sample substances of greater molecular size.