Abstract
The aim of this study was to test the performance of a HPLC method, designated for rapid quantification of chlorogenic acids (CGA) in green coffee extract (GCE). The precision statistics associated with the method were assessed using three independent laboratories with five samples analyzed in triplicate. Seven main CGA isomers (3-CQA, 5-CQA, 4-CQA, 5-FQA, 3,4-diCQA, 3,5-diCQA and 4,5-diCQA) were quantified. The concentration of total CGA in the samples varied from 32.24% to 52.65% w/w. The repeatability and reproducibility standard deviations for the determination of individual isomers varied, respectively, from 0.01 to 0.28 and 0.05–1.59. The repeatability and reproducibility standard deviations of the calculated total CGA, corresponding to the sum of the seven main CGA isomers, varied respectively, from 0.17 to 0.58 and 0.55–2.01. The fast HPLC method evaluated in this study was considered precise and appropriate for the determination of CGA in GCE.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.