Abstract

Arterial hypotension is common after spinal anesthesia (SA) for cesarean delivery (CD), and to date, there is no definitive method to predict it. The hypotension prediction index (HPI) is an algorithm that uses the arterial waveform to predict early phases of intraoperative hypotension. The aims of this study were to assess the diagnostic ability of HPI working with arterial waveforms detected by ClearSight system in predicting impending hypotension in awake patients, and the agreement of pressure values recorded by ClearSight with conventional noninvasive blood pressure (NIBP) monitoring in patients undergoing CD under SA. In this retrospective analysis of pregnant patients scheduled for elective CD under SA, continuous hemodynamic data measured with the ClearSight monitor until delivery were downloaded from an Edwards Lifesciences HemoSphere platform and analyzed. Receiver operating characteristic (ROC) curves were constructed to evaluate the performance of HPI algorithm working on the ClearSight pressure waveform in predicting hypotensive events, defined as mean arterial pressure (MAP) <65 mm Hg for >1 minute. The sensitivity, specificity, positive predictive value, and negative predictive value were computed at the optimal cutpoint, selected as the value that minimizes the difference between sensitivity and specificity. ClearSight MAP values were compared to NIBP MAP values by linear regression and Bland-Altman analysis corrected for repeated measurements. Fifty patients undergoing CD were included in the analysis. Hypotension occurred in 23 patients (48%). Among patients experiencing hypotension, the HPI disclosed 71 alerts. The HPI predicted hypotensive events with a sensitivity of 83% (95% confidence interval [CI], 69-97) and specificity of 83% (95% CI, 70-95) at 3 minutes before the event (area under the curve [AUC] 0.913 [95% CI, 0.837-0.99]); with a sensitivity of 97% (95% CI, 92-100) and specificity of 97% (95% CI, 92-100) at 2 minutes before the event (AUC 0.995 [95% CI, 0.979-1.0]); and with a sensitivity of 100% (95% CI, 100-100) and specificity 100% (95% CI, 100-100) 1 minute before the event (AUC 1.0 [95% CI, 1.0-1.0]). A total of 2280 paired NIBP MAP and ClearSight MAP values were assessed. The mean of the differences between the ClearSight and NIBP assessed using Bland-Altman analysis (±standard deviation [SD]; 95% limits of agreement with respective 95% CI) was -0.97 mm Hg (±4.8; -10.5 [-10.8 to -10.1] to 8.5 [8.1-8.8]). HPI provides an accurate real time and continuous prediction of impending intraoperative hypotension before its occurrence in awake patients under SA. We found acceptable agreement between ClearSight MAP and NIBP MAP.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.