Abstract

Pedicle screw (PS) malpositioning rates are high in spine surgery. This has resulted in the use of computed navigational aids to reduce the rate of malposition; but these are often expensive and limited in availability. A simple mechanical device to aid PS insertion might overcome some of these disadvantages. The purpose of this study was to determine the demand and design criteria for a simple device to aid PS placement, as well as to collect opinions and experiences on PS surgery in the UK and Ireland. A postal questionnaire was sent to 422 spinal surgeons in the UK and Ireland. 101 questionnaires were received; 67 of these (16% of total sent) contained useful information. 78% of surgeons experienced problems with PS placement. The need for a simple mechanical device to aid PS placement was expressed by 59% of respondent surgeons. The proportion of respondents that inserted PSs in the cervical spine was 14%; PSs are mainly inserted in the thoracic, lumbar and sacral spine, but potential exists for a PS placement aid for the cervical and thoracic spine. From the experiences of these 67 surgeons, there is evidence to suggest that surgeons would prefer a pedicle aid that is multiple use, one-piece, hand-held, radiolucent, unilateral and uses the line of sight principle in traditional open surgery. Based on the experiences of 67 surgeons, there is evidence to suggest that computed navigational aids are not readily used in PS surgery and that a simple mechanical device could be a better option. This paper provides useful data for improving the outcomes of spinal surgery.

Highlights

  • This study aimed to determine the demand and design criteria for a potential simple device to aid pedicle screw (PS) placement, as well as to collect opinions and experiences on PS surgery in the UK and Ireland

  • 101 questionnaires (24%) were returned, consistent with other surgical surveys [2, 8,9,10]; 67 of these (16% of total sent) contained useful information, which form the basis of the results reported in this paper

  • Do you Think There is a Need for a Simple Device to Aid PS Placement? Please Give Reasons for your Answer

Read more

Summary

Introduction

This study aimed to determine the demand and design criteria for a potential simple device to aid pedicle screw (PS) placement, as well as to collect opinions and experiences on PS surgery in the UK and Ireland. Screw malpositioning is a problem with approximately 20% implanted inaccurately by experienced surgeons [3]. The problem has resulted in the use of navigational aids to reduce the rate of malposition [5]. These navigational aids are often expensive, limited in availability and present problems in some circumstances [6]. A simple mechanical device to aid PS insertion might overcome some of these disadvantages

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call