Abstract
The double-ended guillotine break (DEGB) of the horizontal coaxial gas duct accident is a serious air ingress accident of the high temperature gas-cooled reactor pebble-bed module (HTR-PM). Because the graphite is widely used as the structure material and the fuel element matrix of HTR-PM, the oxidation analyses of this severe air ingress accident have got enough attention in the safety analyses of the HTR-PM. The DEGB of the horizontal coaxial gas duct accident is calculated by using the TINTE code in this paper. The results show that the maximum local oxidation of the matrix graphite of spherical fuel elements in the core will firstly reach3.75⁎104 mol/m3at about 120 h, which means that only the outer 5 mm fuel-free zone of matrix graphite will be oxidized out. Even at 150 h, the maximum local weight loss ratio of the nuclear grade graphite in the bottom reflectors is only 0.26. Besides, there is enough time to carry out some countermeasures to stop the air ingress during several days. Therefore, the nuclear grade graphite of the bottom reflectors will not be fractured in the DEGB of the horizontal coaxial gas duct accident and the integrity of the HTR-PM can be guaranteed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.