Abstract

Outcome of topography-guided excimer laser ablation in conjunction with accelerated, high-fluence cross-linking in corneal ecstatic disease using the NIDEK CXIII equipped with CATz algorithm from the FinalFit software-"Bharat Protocol." Retrospective case record review of 30 eyes of 17 patients of stage 1-3 keratoconus who underwent the procedure was performed. Data collected were for visual acuity, distortion-induced eye pain, and keratometry. Pachymetry, lower order and higher order aberrations, spherical aberrations, and topographic cylinder were documented from by Scheimpflug imaging (Pentacam 70700: Oculus, Wetzlar, Germany). At a minimum follow-up of 6 months (range 6.2-13 months), there was significant improvement in UCVA (P < 0.00001), BCVA (P = 0.0061), decrease in Kmax (P = 0.0349), Ksteep (P < 0.0411), Kflat (P = 0.0099), and pachymetry (P = 0.0001). Significant improvement was also seen in distortion-induced eye pain (27/30 to 2/30; P < 0.00001). A more than two-line improvement in UCVA and BCVA was seen in 23/30 and 17/30 cases, respectively. Ectasia was stabilized in all cases at the last follow-up, and no complications were seen. The "Bharat" Protocol to arrest keratectasia progression and improve corneal regularity is a safe and efficacious alternative as a keratoconus management option. This is the first such study on Nidek Platform for the same.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call