Abstract
Stable water supply to end users is the most important element in water supply systems (WSSs). The portion of energy used by the water distribution system is up to 40% of the total energy consumed by WSSs. To save energy cost for pumping systems, a number of attempts have been made. Especially, an optimization scheme for scheduling the water-pumping operation has attracted the interest of water engineers. In this paper, a binary integer program was applied to optimize pumping schedule of a WSS in Polonnaruwa, Sri Lanka based on the hourly water demands for the next day. The water demands were forecasted by a combined model consisting of an autoregressive integrated moving average (ARIMA) model and an error compensation routine based on exponential smoothing technique. The result showed that the optimization system could reduce the operation cost of the WSS by minimizing electricity for water pumping; electricity cost for pump operation could be reduced by 55%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.