Abstract

AbstractSauter mean drop sizes (d32) generated from a hole distributor in liquid extraction RDC columns were studied under various conditions. Experiments were designed to generate data required to determine the main variables that control the drop sizes in RDCs. Two precise correlations were proposed for predicting d32 in a RDC extraction column. The first was based on operating variables, hole‐distributor diameter, disc speed, column geometry, and system physical properties. The second one considered the same variables, except the column geometry. This model can be used for design purposes. The two correlations are the first of their type to consider the distributor hole inlet diameter in a RDC column. This diameter has been neglected by previous investigators. The maximum standard deviation for all data is 0.75 %, with a maximum absolute error of 6.8 %.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.