Abstract

The goal of this article is to describe the new neutron imaging facility constructed on the 5th radial beamline of the WWR-SM research reactor at the Institute of Nuclear Physics of the Academy of Sciences of the Republic of Uzbekistan (Tashkent, Republic of Uzbekistan). The neutron beam with the dimensions of 90 × 90 mm2 is formed by the collimator system, the characteristic parameter L/D is 600. The two mirror detector system is based on the 6LiF/Zn(Cd)S:Ag scintillation screen and the high-resolution ProLine PL-09000 CCD camera. The design of the experimental facility, the main parameters, and recently obtained results of the neutron radiography and tomography experiments are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.