Abstract

Based on the similarity between a reentrant wave in cardiac tissue and a vortex in fluid dynamics, the authors hypothesised that a new non-dimensional index, like the Reynolds number in fluid dynamics, may play a critical role in categorising reentrant wave dynamics. Therefore the goal of the present study is to devise a new index to characterise electric wave conduction in cardiac tissue and examined whether this index can be used as a biomarker for categorising the reentrant wave pattern in cardiac tissue. Similar to the procedure used to derive the Reynolds number in fluid dynamics, the authors used a non-dimensionalisation technique to obtain the new index. Its usefulness was verified using a two-dimensional simulation model of electrical wave propagation in cardiac tissue. The simulation results showed that electrical waves in cardiac tissue move into an unstable region when the index exceeds a threshold value.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.