Abstract

We use nanometer-sized point contacts to a Co/Cu spin valve to study the giant magnetoresistance (GMR) of only a few Co domains. The measured data show strong device-to-device differences of the GMR curve, which we attribute to the absence of averaging over many domains. The GMR ratio decreases with increasing bias current. For one particular device, this is accompanied by the development of two distinct GMR plateaus, the plateau level depending on bias polarity and sweep direction of the magnetic field. We attribute the observed behavior to current-induced changes of the magnetization, involving spin transfer due to incoherent emission of magnons and self-field effects.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.