Abstract

Hydroxyapatite (HA) thin coating has been coated on titanium substrates by pulsed laser deposition (PLD). Structural and morphological studies by transmission electron microscopy (TEM) and X-ray diffraction (XRD) were performed. The HA film is polycrystalline and irregular with a range size of particulates from 100 nm to 1 μm. Adhesion of the HA films to the Ti substrates was excellent as observed by cross-scanning electron microscopy (X-SEM) and transmission electron microscopy (XTEM). The residual stresses state determined on uncoated Ti substrates was compressive. After deposition of thin PLD HA on titanium substrates at 400°C the residual stress state was in a very low tensile state.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.