Abstract
The grid synchronization unit, which is often based on a phase-locked loop (PLL) or a frequency-locked loop (FLL), highly affects the power converter performance and stability, particularly under weak grid conditions. It implies that a careful stability assessment of grid synchronization techniques (GSTs) is of vital importance. This task is most often based on obtaining a linear time-invariant (LTI) model for the GST and applying standard stability tests to it. Another option is modeling and dynamics/stability assessment of GSTs in the linear time-periodic (LTP) framework, which has received a little attention. In this letter, the procedure of deriving the LTP model for single-phase GSTs is first demonstrated. The accuracy of the LTP model in predicting the GST dynamic behavior and stability is then evaluated and compared with that of the LTI one. Two well-known single-phase GSTs, i.e., the second-order generalized integrator-based FLL (SOGI-FLL) and enhanced PLL (EPLL), are considered as the case studies.