Abstract

This paper mainly focuses on the problems of inaccurate measurement of the primary air flow rate in a coal-fired power plant. The feasibility of improving the uniformity of flow fields and temperature fields by installing double-layer arch cool air distributor and mixed flow matrix was analyzed by the method of numerical simulation. The results show that, the relative standard deviation of the wind speed measurement section of optimization model decreased from 18.7%~18.4% to 9%~9.1%, compared with the original model. Similarly, the relative standard deviation of temperature measurement section also decreased from 15%~14.6% to 1.3%~1.4%. The study suggests that this mixed flow fields equalization solution can effectively enhance the mixing of cool and hot primary air, and can improve the uniformity of the mixed air flow fields, thereby improving the accuracy and reliability of primary air measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.