Abstract

Structures in which γ-ray production instruments are located are made of heavyweight concrete. To determine roof and wall thickness of such structures, it is necessary to measure amount of radiation absorbed. The present study was designed to investigate the effects of mix design parameters such as water to cementations materials ratio, type of aggregates and cement and pozzolanic material contents on γ-ray absorption. This paper determines attenuation coefficient of normal and heavyweight concrete. Absorption of γ-ray was both measured by experimental tests and XCOM software. Results also showed that using barite aggregates increases attenuation coefficient by 30%. Comparison of the compressive strength of normal concrete made of limestone aggregates with that of heavyweight concrete made of barite aggregates showed very close compressive strengths in both types of concrete at high W/CM values. For low W/CM values, however, compressive strength of normal concrete was higher than that of heavyweight.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.