Abstract

Annotation Purpose. Improving the efficiency of machine milking due to the improvement of milking equipment on the basis of the portion meter of the weight type. Methods. Studies have been conducted on the basis of the planned experiment. The data obtained were processed using the methods of regression analysis. Results. The technique of laboratory researches is developed, a prototype of a membrane regulator of vacuum is made and experimental researches of operating modes of the adaptive milking equipment on the basis of the portion meter of the weight type. According to the results of the research, the dependence between the parameters and the mode of operation of the membrane vacuum regulator was obtained. Conclusions. The dependence is obtained, between the vacuum pressure in the milk collection chamber of the collector, milk expense, the diameters of the milk pipe and the diameters of a throttle opening. The limit values of the intensity of milk output (0.2 m3/s) at which there is a critical drop in the working vacuum pressure in the milk collection chamber of the collector and the corresponding choke parameters (diameter of the throttle opening 0,001 m) are defined. This eliminates this negative phenomenon. Keywords: adaptive milking equipment, milking machine, machine milking, milk expense.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call