Abstract

Magnetic nanoparticle-assisted solid-phase dispersion (MMSPD) combined with dispersive liquid–liquid microextraction (DLLME) prior to high performance liquid chromatography with fluorescence detector (HPLC–FLU) is presented for determination of ultra trace Bisphenol A (BPA) in water. Magnetic multi-walled carbon nanotubes (MMWCNTs) were synthesized for the adsorption of BPA in water. Ultra trace BPA in water was transferred into the elute solvent by the MMSPD and further concentrated into trace volume extraction solvent by the DLLME. The limit of detection and limit of quantitation were 0.003 and 0.01 µg L−1, respectively. Good linearity of BPA was found, ranging from 0.01 to 10 µg L−1, with good squared regression coefficient (R 2) of 0.9999. Additionally, relative recoveries were 83.1 and 95.9% for two environmental water samples spiked with 0.20 µg L−1 BPA, respectively. All results showed that the MMWCNTs nanoparticle-assisted MMSPD–DLLME–HPLC–FLU method was simple and reliable for the determination of ultra trace BPA in environmental water.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.