Abstract

High resistivity and high oxygen concentration of silicon wafers can be beneficial for the radiation hardness of silicon detectors. Wafers of Magnetic Czochralski silicon (MCz-Si) can be grown with a resistivity of a few k Ω cm and with well-controlled, high oxygen concentration. According to the beam test results presented in this paper, n-type MCz-Si bulk, p-strip readout detectors with can be operated with acceptable signal-to-noise ratio up to the irradiation fluence of 1×10 15 cm −2 1-MeV neutron equivalent. The improved radiation hardness compared to that of traditional p-in-n Float Zone silicon (p-in-n FZ-Si) detectors can be explained by better electric field distribution inside MCz-Si detectors. The difference between the distributions is clearly shown by Transient Current Technique (TCT) measurements, presented in this paper. Thus, strip detectors made on n-type MCz-Si are a feasible option for the outer tracker layers of the potential upgrade of the Large Hadron Collider (LHC), the Super-LHC. This corresponds approximately 95% of the total area of silicon detectors in the Super-LHC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.