Abstract

Power plants need to reduce operating costs to be competitive, by eliminating correctable causes of wasted energy and minimizing lost revenue due to forced outages. The main cause of these problems is the excessive air in-leakage in condensers. High air-leakage causes turbine back pressure to rise, dissolved oxygen (DO) concentration to increase and the plant heat rate (CE) to deteriorate to higher values. The development of methods to detect air in-leakage has involved from the methods based of foam, smoke and various audio methods, but it generated high levels of uncertainty. The method discussed in this study is the trace gas method, using helium (He), which has been tested in a power plant of 550 MW, with good results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.