Abstract

For urban heating pipeline network, the intelligent and precise detection is an important guarantee for urban heating infrastructure of the safe and low-carbon operation. Heating pipe network was directly buried in the soil and difficult to detect the leakage point due to lack of non-excavation detection method for rapid repair. An improved noise reduction algorithm of the wavelet threshold function coupled with the acoustic method was used for the directly buried pipe leakage detection. Large-scale leakage experimental tests were used to validate the reliability. The influences of temperature, pressure, flowrates and leakage distance on the frequency and time domains were then investigated. Results show that the improved threshold function could well detect the leakage for directly buried hot water heating pipes. When the temperature increases, the leakage frequency domain spreads from 200 - 800 Hz to 50–1500 Hz. The pressure, flow rate, and leak point location could affect the amplitude feature. The accuracy ranges of the improved method in the different location, temperature and pressure and flowrates are separately 0.11–2.36%, 0.11–1.96%,0.11–3.49% and 0.16–1.55%, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.