Abstract

Abstract In this study, laser damage tests of multilayer dielectric gratings (MDGs) are performed in vacuum (5×10 −4 Pa) and in air at a wavelength of 1053 nm with pulse widths of 0.56 ps ~9.7 ps. The laser-induced damage threshold (LIDT) of MDGs in vacuum/air ranges from 2.1/2.2 J/cm 2 to 4.4/4.8 J/cm 2 for laser beams of normal incidence. The LIDT of MDGs follows a τ 0.26 scaling in the pulse width regime considered. The typical damage morphologies in the two environments caused by the near threshold pulse were observed using a scanning electron microscope (SEM); the results indicate that the damage features of MDGs in vacuum are the same as those in air. The testing results reveal that a clean vacuum environment neither changes the laser damage mechanism nor lowers the LIDT of MDGs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call