Abstract

Historical data suggest 15% of laboratory animal workers develop IgE sensitisation and 10% symptoms of laboratory animal allergy (LAA), including occupational asthma. Individually ventilated cages (IVCs) are replacing conventional open cages; we sought to evaluate their impact on the development of LAA. We surveyed 750 laboratory animal workers and measured airborne Mus m 1 (mouse allergen) levels in seven UK institutions. We compared the prevalence of sensitisation to mouse proteins (by specific IgE assay or skin prick test) and of work-related allergic symptoms in IVC-only and open cage units. Full-shift Mus m 1 levels were lower in IVC than open cage units (geometric mean 1.00 (95% CI 0.73-1.36) versus 8.35 (95% CI 6.97-9.95) ng·m-3; p<0.001), but varied eight-fold across the IVC units (geometric mean range 0.33-4.12 ng·m-3). Primary analyses on data from 216 participants with ≤3 years exposure to mice revealed a lower prevalence of sensitisation in those working in IVC units compared with conventional cage units (2.4% (n=2) versus 9.8% (n=13); p=0.052). Sensitisation in IVC units varied from 0% to 12.5%; the use of fitted respiratory protection was less common in IVC units where prevalence of sensitisation was higher. Work-related allergy symptoms were more frequently reported by mouse-sensitised individuals (46.7% versus 10.9%; p<0.001) and only by those working in open cage units. In contemporary practice, LAA is now largely preventable with the use of IVC systems and the judicious use of appropriate respiratory protection.