Abstract
Transformer is one of the crucial components in an electrical system. They are used to convert energy to a utilization level. Load allocation is vital to sustaining the needed energy demand for a growing population, and it is an essential consideration for continuous consumer connectivity of electricity. In this study, the researchers are conducting assessment and forecast of the transformer requirement for a Low Voltage Private Academic Institution. It assessed the kWh demands and kWh allocation from 2005 to 2019 of the three transformers used of the locale. The kWh demand was used to forecast the per semiannual for the next five years. Six forecasted models were applied and the result were verified by QM for Windows Version 5. Mean Absolute Error (MAE), Mean Square Error (MSE) and Mean Absolute Percent Error (MAPE) were used to select the best forecasting model with the least value. DT (Distribution Transformer) 1 used the 4th degree polynomial model because of the least value of MAE, MSE and MAPE of 5340.626, 42306100 and 17.12%, while DT 2 and DT 3 applied the 3 rd degree polynomial model though it has the second lowest value of MAE, MSE and MAPE of 3142.907, 16748570, 20.44% and 2576.398, 8740315, 11.21% respectively because the projected demand of the 4th degree gave a negative value.. The researcher finds that DT 1 and 3 were starting to exceeds the allotted kWh. On the other hand, DT 2 and 4 were plenty of kWh allocation. Relocation of load from DT 1 and 3 to DT 2 may take for considerations by the institution.
Highlights
Transformers were widely used in an electrical power system, whether in the generation system, transmission system and distribution system
In a distribution power system, distribution transformers were usually installed in an operating range of 13,800 primary voltage input to a secondary output voltage of 230 volts
Transformers in the distribution system are classified to be either: Manuscript received on January 12, 2021
Summary
Transformers were widely used in an electrical power system, whether in the generation system, transmission system and distribution system. Transformers function is to transform energy to usable level to utilize by people. In a distribution power system, distribution transformers were usually installed in an operating range of 13,800 primary voltage input to a secondary output voltage of 230 volts. Transformers in the distribution system are classified to be either: Manuscript received on January 12, 2021. Revised Manuscript received on April 10, 2021.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Engineering and Advanced Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.