Abstract

Objective: To establish a method for the determination of n-butylamine in the air of the workplace by ion chromatography. Methods: In February 2022, on-site sampling was carried out using an atmospheric sampler. N-butylamine was adsorbed by a neutral silica gel tube and then performed for qualitative and quantitative determination by ion chromatography after ultrasonic desorption with 10 mmol/L sulfuric acid solution. Results: The linear range of the method was 0.0375-100.0 μg/ml, the linear equation of the standard curve was y=0.0713x-0.0327, the correlation coefficient was 0.9992. The detection limit of the method was 11.25 μg/L, and the lower limit of quantification was 37.50 μg/L, the lowest quantitative concentration was 0.025 mg/m(3) (in term of sampling 7.5 L). The average desorption efficiency of the method was 91.50%-95.38%, the precision was 1.10%-2.30%, the standard recovery was 83.83%-100.02%, sampling efficiency was 100.00%. Conclusion: This method is fast, sensitive and accurate, and can be used for the determination of n-butylamine in the air of workplace.