Abstract

Objective: To establish a method for the determination of ethylamine in the air of the workplace by ion chromatography. Methods: In August 2020, ethylamine in the air of the workplace was adsorbed by a basic silica gel tube, and ultrasonically desorbed with a 1 mmol/L sulfuric acid solution, and then qualitatively and quantitatively determined by ion chromatography. Results: The linear range of the method was 0.014-50 μg/ml, and the linear equation of the standard curve was y=0.1243x+0.0429, the correlation coefficient was r=0.9997. The detection limit of the method was 4.29 μg/L, and the lower limit of quantification was 14.29 μg/L. The lowest quantitative concentration was 0.012 mg/m(3) (in term of sampling 6.0 L) . The average desorption efficiency of the method was 97.31%, the precision was 1.00%-1.68%, and the standard recovery rate was 96.33%-99.61%. Conclusion: This method is fast, sensitive and accurate, and can be used for the determination of ethylamine in the air of workplace.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.