Abstract

This study presents exergy analysis for forced convection heat transfer in shell and helically coiled tube heat exchangers. The effect of operational and geometrical parameters on the exergy efficiency was investigated. Water is selected as the working fluid of both sides. Results show that, the efficiency decreases linearly with the increase of the fluids dimensionless inlet temperature difference. Based on the results, a correlation was developed to predict the efficiency for wide range of mass flow rates ratio (0.1<Rm<4), fluids dimensionless inlet temperature difference (0<RT<0.8), product of Reynolds numbers (3.31E+8<(Rec. Resh)<1.32E+9) and dimensionless geometrical parameters. According to this equation it was found that, the coil which has the maximum number of turns and minimum diameter is more efficient than other coils which have the same length and pitch.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.