The paper gives the results of measurements of the influence of plastic deformations in the time-decrease of permeability in hot rolled transformer steel. In the first part measurements were performed on samples rolled in a mill. The measurements showed a drop of time decrease of permeability at large elongations and a maximum at small elongations. In the second part measurements were performed on samples stretched in a tensile testing machine. The results of measurements are characterized by typical wavy shape of time decrease of permeability. The obtained results are connected with the variations of lengths of the paths of impurities diffusing in the crystal lattice.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.