Lipid peroxidation by free radicals has been suggested as a mechanism of a lung injury caused by breathing higher than normal concentrations of oxygen. The appearance of hydrocarbons such as n-pentane in the expired gas of mammals has been proposed as in vivo evidence of lipid peroxidation. The excretion of n-pentane was studied in 15 healthy volunteers in whom excretion of exogenous n-pentane was determined over a 60- to 90-min period while breathing hydrocarbon-free gases. N-pentane elimination rates (mean +/- SEM) in the expired gas at 0, 30, 60, 90, and 120 min were 10.2 +/- 1.5, 1.6 +/- 0.2, 1.2 +/- 0.9, 1.3 +/- 0.4, and 1.3 +/- 0.3 (pmol X kg-1 X min-1), respectively. Using a specially assembled circuit, a 2-h oxygen exposure study was performed on six healthy volunteers, in whom basal n-pentane excretion varied ten-fold among individuals, from 0.25 to 2.25 pmol X kg-1 X min-1. After breathing 100% oxygen, n-pentane excretion was augmented 62-420% within 30 to 120 min. The authors conclude that lipid peroxidation may occur in humans within 30 min of breathing 100% oxygen.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.