Abstract

In order to ensure the quality and the relevance of irradiation programs in the future Jules Horowitz Reactor (JHR), the French Alternative Energies and Atomic Energy Commission (CEA) has significantly increased its research and development effort in the field of in-pile instrumentation during the last decade. Major progress has been achieved in the capability to perform accurate in-pile measurements using reliable and updated techniques. A significant part of this effort has been conducted in the framework of the Joint Instrumentation Laboratory between the CEA and the Belgian Nuclear Research Centre (SCK $\cdot$ CEN). In order to improve measurement techniques for neutron flux assessment, a unique system for online measurement of fast neutron flux has been developed and recently qualified in-pile. The fast-neutron-detection-system (FNDS) has been designed to monitor accurately high-energy neutron flux (E > 1 MeV) in typical material testing reactor (MTR) conditions, where neutron flux levels can be as high as $10^{15}\,\,\text {N}\cdot \text {cm}^{-2}\cdot \text {s}^{-1}$ and are generally dominated by thermal neutrons. Moreover, the neutron flux is coupled with a high gamma flux of typically a few $10^{15} \gamma \cdot \text {cm}^{-2}\cdot \text {s}^{-1}$ , which can be highly disturbing for the online measurement of neutron fluxes. The patented FNDS system is based on two detectors allowing the simultaneous detection of both thermal- and fast-neutron flux. Thermal neutrons can be measured using a self-powered neutron detector or a 235U miniature fission chamber, while fast neutron detection requires a miniature fission chamber with a special fissile material presenting an energy threshold near 1 MeV, which can be 242Pu for MTR conditions. Fission chambers are operated in Campbelling mode for an efficient gamma rejection. FNDS also includes a specific software that processes measurements to compensate online the fissile material depletion and to adjust the sensitivity of the detectors, in order to produce a precise evaluation of both thermal and fast neutron flux even after long-term irradiation. FNDS has been validated through a two-step experimental program. A first set of tests was performed at BR2 reactor operated by SCK $\cdot$ CEN in Belgium. Two FNDS prototypes were operated in-pile during nearly 1000 h. These tests exhibited the consistency of the measurement of thermal to fast neutron flux ratio with Monte Carlo neutron and photon transport calculations, as well as the right compensation of fissile material depletion. This paper describes a second test recently completed at ISIS reactor operated by CEA in France. For this irradiation, FNDS signal was compared to reference thermal- and fast-neutron flux measurements using activation dosimeters analyzed under COFRAC Quality Certification. During this latter test, FNDS proved its ability to measure online the fast neutron flux with an overall accuracy better than 5%. FNDS is now operational and is assumed to be the first and unique acquisition system able to provide an online measurement of the fast neutron flux in MTR conditions. This system will be used to perform spectral neutron characterization of JHR channels, but it may also be implemented in future irradiation experiments, for a better and real-time evaluation of the fast neutron flux received by material and fuel samples.

Highlights

  • FAST neutron flux (E ≥ 1 MeV) is a key neutron parameter in nuclear reactors

  • In more powerful reactors, such as Material Testing Reactors (MTRs) or nuclear power plants (NPPs), techniques used in ZPRs are not appropriate

  • The results of this experiment confirm the quality of the on-line fast neutron flux measurements at a few 1011 n.cm-2.s-1 (E > 1 MeV) with this type of miniature fission chambers and confirm FNDS capability to measure in real-time the absolute thermal and fast neutron fluxes with an excellent accuracy

Read more

Summary

INTRODUCTION

FAST neutron flux (E ≥ 1 MeV) is a key neutron parameter in nuclear reactors. Its measurement is relevant to assess material damage under irradiation. In more powerful reactors, such as Material Testing Reactors (MTRs) or nuclear power plants (NPPs), techniques used in ZPRs are not appropriate This is mainly due to the rapid evolution of the fissile coating under high neutron flux that reduces the sensitivity of the sensor to the ‘fast’ spectrum domain (cf II.B). In order to ensure the quality and the relevance of irradiation programs in the future Jules Horowitz Reactor (JHR), the French Alternative Energies and Atomic Energy Commission (CEA) has significantly increased its research and development effort in the field of in-pile instrumentation during the last decade In this context and in the framework of the Joint Instrumentation Laboratory between the CEA and the Belgian Nuclear Research Centre (SCKCEN), a measurement system dedicated to on-line measurement of fast neutron flux has been developed

FNDS SPECIFICATIONS
Geslot is with the Alternative Energies and Atomic Energy Commission
Acquisition system
Processing software
IN-PILE QUALIFICATION OF FNDS
Findings
CONCLUSION

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.