Abstract

Diesel particulate filters (DPF) are indispensable parts of modern automotive exhaust gas aftertreatment systems due to the stringent emissions legislation. For a fuel-efficient control strategy, it would be beneficial to determine directly and in-operation their actual trapped soot mass. Two novel approaches—based on the electrical conductivity of trapped soot particles—emerged recently. By measuring the electrical resistance between different single walls inside the filter, the soot load is determined with local resolution. The microwave-based technique is a contactless approach that gives an integral value depending on the soot mass in the DPF. We present investigations on loading and regeneration of DPFs in a dynamometer test bench applying both methods. The results are compared with each other and correlated with the differential pressure and the soot mass. Especially the microwave-based technique has a potential for serial application.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.