Abstract

Electromagnetic valve for controlling the refrigerant flow is attached to pipe in air conditioning units. Excitation force is generated in the pipe when electromagnetic valve opens and the refrigerant flows. Focusing on this excitation force, we carried out the experiment using refrigerant circulation system. On the other hand, pressure and the flow velocity in the pipe are calculated by fluid analysis. After that, using the pressure and the velocity, we calculated excitation force according to the momentum principle. We found that calculation results both excitation force and displacement of pipe agreed well with experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.