Abstract

A sensitive rapid high-performance liquid chromatographic assay for hydroxychloroquine and three major metabolites, desethylhydroxychloroquine,desethylchloroquine and bisdesethylchloroquine, has been developed. An ion-suppression separati a macroporous polymer, poly(styrene divinylbenzene), stationary phase and a mobile phase of methanol—water with triethylamine, pH 11. A single ether extraction from alkalinized plasma or whole blood, with chloroquine added as an internal standard, is used. Using fluorescence detection, with excitation at 337 nm, the limit of sensitivity is 1 ng/ml. Some anti-inflammatory drugs which may be used concurrently for rheumatoid disorders are shown not to interfere with the assay. Samples of whole blood and plasma obtained from rheumatoid patients contained hydroxychloroquine and all three metabolites.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.