Abstract

A sensitive and rapid high-performance liquid chromatographic assay is developed and validated for the determination of buformin in plasma. After addition of metformin as the internal standard, the analytes were deproteinated with acetonitrile, washed with dichloromethane, and the resulting supernatant injected. Chromatography was performed at ambient temperature by pumping a mobile phase of 0.03 m diammonium hydrogen phosphate buffer (pH 7, 250 mL) in methanol (750 mL) at a fl ow rate of 1 mL/min through a silica column. Buformin and metformin were detected at 236 nm, and eluted 9.8 and 15.4 min, respectively. No endogenous substances were found to interfere. Calibration curves were linear over the concentration range of 20-2000 ng/mL. The limit of quantitation was 20 ng/mL. The intra- and inter-day relative standard deviation (RSD) was 8.3%, or less, and the accuracy was within 10.1% of the relative error (RE). The method is suitable in pharmacokinetic investigation of buformin.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.