Abstract
A new finishing method was developed to correct the thickness distribution of a quartz crystal wafer by the numerically controlled scanning of a localized atmospheric pressure plasma. The thickness uniformity level of a commercially available AT-cut quartz crystal wafer was improved to less than 50 nm without any subsurface damage by applying one correction process. Furthermore, applying a pulse-modulated plasma markedly decreased the correction time of the thickness distribution without breaking the quartz crystal wafer by thermal stress.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.