Abstract

BackgroundVideo-assisted thoracoscopic surgery (VATS) is an emerging technology in minimally invasive surgery, which has become recognized as standard treatments for early-stage lung cancer. Microcoil localization is considered to be a safe and effective way of preoperative localization, and is essential to facilitate VATS wedge-resection for lung nodules.Case presentationHere we report a rare case of a 28-year-old female who developed hemorrhagic shock caused by delayed pneumothorax after preoperative computed tomography (CT)-guided microcoil localization. The thoracic CT revealed hydropneumothorax in the right thoracic cavity at 10 h after microcoil localization, and the patient later had significant decreased hemoglobin level (87 g/L). Emergency thoracoscopic exploration demonstrated that the hemorrhagic shock was induced by delayed pneumothorax, which led to the fracture of an adhesive pleura cord and an aberrant vessel. Electrocoagulation hemostasis was then performed for the fractured vessel and the patient gradually recovered from the hypovolemic shock.ConclusionsMicrocoil localization is a relatively safe and effective way of preoperative localization of lung nodules, however, hemorrhagic shock could be induced by rupture of pleural aberrant vessels subsequent to puncture related pneumothorax. Shorten the time interval between localization and thoracoscopic surgery, extend the monitoring time after localization might help to reduce the risk of these complications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call