Abstract
The convective heat transfer characteristics of Al2O3/water and CNT/water nanofluids through uniformly heated horizontal circular tube in transition regime with helical twisted tape inserts are estimated experimentally. Tests were performed with varied range of particle volume concentration (0.15%, 0.45%, 0.60% and 1%) and helical tape inserts of twist ratio (TR)=1.5, 2.5 and 3. It is observed that the heat transfer performance of both the nanofluids increases with the increase in the particle volume fraction. The CNT/water nanofluids with helical screw tape inserts exhibits higher thermal performance compared to Al2O3/water nanofluid. The maximum enhancement in heat transfer was obtained by using CNT/water nanofluid (ϕ=1%) with helical tape inserts of twist ratio 1.5. For all the twist ratio of helical screw tape inserts the pressure drop for Al2O3 nanofluid with helical screw tape inserts is higher compared to the CNT nanofluid.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Chemical Engineering and Processing: Process Intensification
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.