Abstract

BackgroundGuided endodontics technique has been introduced for years, but the accuracy in different types of teeth has yet to be assessed. The aim of this study is to evaluate the accuracy of three dimensional (3D)-printed endodontic guides for access cavity preparation in different types of teeth, and to evaluate the predictive ability of angular and linear deviation on canal accessibility ex vivo.MethodEighty-four extracted human teeth were mounted into six jaw models and categorised into three groups: anterior teeth (AT), premolar (P), and molar (M). Preoperative cone beam computed tomography (CBCT) and surface scans were taken and matched using implant planning software. Virtual access cavity planning was performed, and templates were produced using a 3D printer. After access cavities were performed, the canal accessibility was recorded. Postoperative CBCT scans were superimposed in software. Coronal and apical linear deviations and angular deviations were measured and evaluated with nonparametric statistics. The receiver operating characteristic (ROC) curve was used to evaluate the predictive ability of angular and linear deviation for canal accessibility in SPSS v20.ResultsA total of 117 guided access cavities were created and 23 of them were record as canal inaccessibility, but all canals were accessible after canal negotiation. The average linear deviation for all groups was 0.13 ± 0.21 mm at coronal position, 0.46 ± 0.4 mm at apical position, and 2.8 ± 2.6° in angular deviation. At the coronal position, the linear deviations of the AT and P groups were significantly lower than M group deviation (P < 0.05), but no statistically significant difference between AT group and P group. The same results were found in linear deviation at the apical position and in angular deviation. The area under the ROC curve was 0.975 in angular deviation, 0.562 in linear deviation at the coronal position, and 0.786 at the apical position. Statistical significance was noted in linear deviation at the apical position and in angular deviation (P < 0.001).ConclusionsIn conclusion, this study demonstrated that the accuracy of access cavity preparation with 3D-printed endodontic guides was acceptable. The linear and angular deviations in the M group were significantly higher than those in the other groups, which might be caused by the interference of the opposite teeth. Angular deviation best discriminated the canal access ability of guided access cavity preparation.Graphical

Highlights

  • Guided endodontics technique has been introduced for years, but the accuracy in different types of teeth has yet to be assessed

  • The same results were found in linear deviation at the apical position and in angular deviation

  • Statistical significance was noted in linear deviation at the apical position and in angular deviation (P < 0.001)

Read more

Summary

Introduction

Guided endodontics technique has been introduced for years, but the accuracy in different types of teeth has yet to be assessed. The aim of this study is to evaluate the accuracy of three dimensional (3D)-printed endodontic guides for access cavity preparation in different types of teeth, and to evaluate the predictive ability of angular and linear deviation on canal accessibility ex vivo. PCO is characterised by deposition of hard tissue in the root canal space. This is usually due to luxation injuries after dental trauma [3] and can be caused by carious lesions [4], coronal restorations [5], and pulp capping [6]. The combination of dental operating microscopy (DOM) and an ultrasonic tip can be used to identify obliterated canals [7]. In endodontic treatment, cone beam computed tomography (CBCT) can provide additional information via three-dimensional (3D) views [9]; the use of CBCT has been suggested for localising calcified canals [10]

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.