Abstract

This study presents the implementation of Artificial Bee Colony (ABC) optimization in an island hybrid power system model using fuzzy logic-based load frequency control. The Island Hybrid Power System considered in this study consisted of various generation units and an energy storage system. The optimized control parameters of PID using ABC were used in an intelligent fuzzy logic controller. The profiles (power & Frequency) of isolated hybrid power system were improved using a Super Conducting Magnetic Energy Storage (SMES) System. Individual controllers were used for wind turbine and diesel generators to control the power output for balancing the demand (frequency change control). Comparative analysis of power and frequency with the help of various classical and intelligent control configurations is presented. The outcome of the study shows that a minimum deviation in frequency and power is obtained through the proposed Intelligent Fuzzy Control approach for the considered isolated power system model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.