Abstract

Over the past few years, multiple types of modifications have been proposed onto the Direct Torque Control (DTC) scheme. Among others is the implementation of Space Vector Modulation (SVM). In this paper, two new control strategies are proposed onto an SVM-DTC. Instead of using PI torque and flux controllers, a fuzzy logic control method is implemented in the proposed modification to achieve a more constant switching frequency while minimizing the torque error. The fuzzy logic controller controls the voltages in direct and quadratic reference frame (Vd, Vq). This approach fully utilizes the switching capability of the inverter and thus improving the overall system performance. To overcome issues in open loop stator flux such as DC drift and saturation, a closed loop estimation method of stator flux is also proposed based on voltage model and low pass filter. The performance of the proposed control strategy is benchmarked with that of a conventional DTC–SVM. Simulations and experiments were carried out and the results show that the proposed method outperforms the conventional DTC-SVM in terms of DC-offset elimination and overall system robustness. <p class="MsoNormal" style="text-align: justify; text-indent: 36.0pt;"><span style="font-size: 9.0pt; font-family: 'Arial','sans-serif'; color: black;" lang="EN-US">Over the past few years, multiple types of modifications have been proposed onto the Direct Torque Control (DTC) scheme. Among others is the implementation of Space Vector Modulation (SVM). In this paper, two new control strategies are proposed onto an SVM-DTC. Instead of using PI torque and flux controllers, a fuzzy logic control method is implemented in the proposed modification to achieve a more constant switching frequency while minimizing the torque error. The fuzzy logic controller controls the voltages in direct and quadratic reference frame (V<sub>d</sub>, V<sub>q</sub>). This approach fully utilizes the switching capability of the inverter and thus improving the overall system performance. To overcome issues in open loop stator flux such as DC drift and saturation, a closed loop estimation method of stator flux is also proposed based on voltage model and low pass filter. The performance of the proposed control strategy is benchmarked with that of a conventional DTC–SVM. Simulations and experiments were carried out and the results show that the proposed method outperforms the conventional DTC-SVM in terms of DC-offset elimination and overall system robustness. </span></p>

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.