Abstract

Abstract A sensitive kinetic fluorimetric flow injection method has been developed for the determination of Ag(I) over the range 100–2500 ng. The method is based on the catalytic effect of Ag(I) on the reduction reaction of safranine by iodide. Method development includes optimization of reagent concentration, pH, reaction temperature, and flow variables. The optimized flow injection manifold yielded a detection limit of 50 ng of Ag(I). Chemical interference studies showed that the method also has good selectivity. The method was applied to the determination of silver in expired black and white photographic film.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.