Abstract
A fiber optic sensor device has been developed incorporating a short length of erbium doped fiber fused in close proximity to a single-fiber Bragg grating, to measure both the fluorescent lifetime decay and the wavelength shift in these respective elements, for temperature and strain determination. Calibration results obtained from this simple, low cost, intrinsic sensor scheme show standard deviation errors of 20.4 με and 1.2 °C over strain and temperature ranges of 22–1860 με and 25–120 °C, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.