Abstract

Nanolayer and nanolayer by nanolayer deposition of nanofilms of Ag and C using cold plasma in sequences (Ag, Ag-C, Ag-Ag-C), on porous paper, were used to design three disposable stochastic sensors for the assay of amyloid polypeptide from whole blood. The nanofilms were modified with α-cyclodextrin. The test developed using the nanofilm-based disposable stochastic sensors is used for early detection of diabetes. The wider linear concentration range (1.00 × 10-6-1.00ngmL-1) and the lower limit of quantification (1.00 × 10-6ngmL-1) were obtained using the disposable stochastic sensors based on Ag-C and Ag-Ag-C, while the highest sensitivity (3.19 × 104s-1/μgmL-1) was recorded using the disposable stochastic sensor based on Ag-Ag-C. The screening methods were fully validated using whole blood samples from confirmed patients, when the recovery of the islet amyloid polypeptide was higher than 98.00%. Graphical abstract.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.