Abstract

Introduction: The fourth-generation ELISA human immunodeficiency virus (HIV) screening test has a high sensitivity and specificity >99% to detect both antigens and antibodies. Estimates are that only 0.5% yield false positive results.Case description: 61-year-old female patient with a clinical picture consisting of malaise, unquantified fever, asthenia and adynamia. Laboratory tests revealed anemia, so a Coombs test was performed, obtaining a positive result along with other findings of mixed autoimmune hemolytic anemia. Two fourth-generation ELISA HIV screening tests were performed obtaining positive results. Given the national recommendations on the diagnosis of HIV infection, a viral load was performed, which turned out to be negative, so the result was considered a false positive.Discussion: Clinical and biological factors are related to false positive results. There are descriptions about autoimmunity phenomena, such as systemic lupus erythematosus or autoimmune hemolytic anemia, with few cases in older adults.Conclusions: Rapid tests have changed the diagnosis of HIV infection worldwide; however, like any other diagnostic test, they may yield false positive results with differential diagnoses, including autoimmune hemolytic anemia.

Highlights

  • The fourth-generation ELISA human immunodeficiency virus (HIV) screening test has a high sensitivity and specificity >99% to detect both antigens and antibodies

  • Rapid tests have changed the diagnosis of HIV infection worldwide; like any other diagnostic test, they may yield false positive results with differential diagnoses, including autoimmune hemolytic anemia

  • The recommendations of the national guidelines for the diagnosis of HIV infection (7) were followed and a second test was performed, which was positive with a value of 0.29. Considering these results and following again the recommendations of the national guidelines (7), a viral load test was performed, obtaining negative results. This is the case of an older patient with autoimmune hemolytic anemia, with suspected systemic lupus erythematosus (SLE) by nephrotic syndrome and weakly positive antinuclear antibodies

Read more

Summary

Introduction

The fourth-generation ELISA human immunodeficiency virus (HIV) screening test has a high sensitivity and specificity >99% to detect both antigens and antibodies. Estimates are that only 0.5% yield false positive results. Case description: 61-year-old female patient with a clinical picture consisting of malaise, unquantified fever, asthenia and adynamia. Laboratory tests revealed anemia, so a Coombs test was performed, obtaining a positive result along with other findings of mixed autoimmune hemolytic anemia. Two fourth-generation ELISA HIV screening tests were performed obtaining positive results. Given the national recommendations on the diagnosis of HIV infection, a viral load was performed, which turned out to be negative, so the result was considered a false positive

INTRODUCTION
DISCUSSION
ETHICAL CONSIDERATIONS
Full Text
Published version (Free)