Abstract

AbstractA new Fabry–Perot (FP) microcavity structure with a novel single deeply corrugated diaphragm (SDCD) is presented for use in pressure sensing. Both analytical expression and finite‐element model (FEM) are used to evaluate the device's performance. The FP microcavity is fabricated on a single chip using both surface and bulk micromachining techniques. The results show that the signal averaging effect can substantially be reduced for the FP microcavity pressure sensor by the flatness‐enhancing diaphragm structure. © 2003 Wiley Periodicals, Inc. Microwave Opt Technol Lett 39: 240–243, 2003; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.11180

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.