Abstract

Fire smoke movement of multi-floor and multi-room (MFMR) fire was studied at the model test building in State Key Laboratory of Fire Science (SKLFS). The ingredient, temperature, air pressure difference and air velocity of smoke were measured and analyzed. Meanwhile, the hazard of smoke ingredient to exposed occupants was analyzed based on the national standard, Occupational Exposure Limit for Hazardous Agents in the Workplace (GBZ2-2002). The experimental results showed that the maximum temperature difference in MFMR fire was located along the vertical height from the fire source. With the spreading and diffusion of smoke, the temperature of smoke layer would tend to be no difference. In the fire of woodpile and kerosene, the main smoke ingredients such as SO 2 , CO and CO 2 would first exceed human’s average physiological limit, while smoke ingredients such as NO and NO 2 would come behind. Because of the higher fluctuation range and frequency of air pressure difference of smoke in multi-layer building fire, the fire smoke would spread around everywhere of the passageway and made the human evacuation more difficult.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.