Abstract

In this work, experimental investigation is carried out to understand influence of twisted tape and internal coil on heat transfer characteristics in a circular tube. The work focuses on experimental investigation of heat transfer & friction factor characteristics of horizontal circular pipe by the means of inserts, with air as working fluid. Nusselt number & friction factor obtained experimentally were validated against those obtained from theoretical correlations. The twisted tapes used are of three different twist ratios such as 1.78, 2.32 and 2.77. Also a coil is inserted tightly in a pipe. Initially experiment was carried out for plain tube at constant wall heat flux & different mass flow rates of air. Secondly experiment was carried out with insertions in a tube for the same working conditions as that of plain tube. The experimental results obtained were compared with those obtained from plain tube.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.